X-REL-8i
X-REL-8i
Description
Relay outputs
The module provides 8 relay outputs. Each relay supports 1 changeover and 1 on or 1 off switch (depending on the module version). All 16 switches are ellectrically isolated among each other.
Watchdog
If the watchdog is activated, it must be triggered at least once within the timeout period. If this remains undone the watchdog switches all relays to its rest state. This can cause an interrupt.
Specifications
Parameter | Value | Unit |
Relais: | ||
- Number | 8 | - |
- Contact resistance | 100 | mOhm |
- Switching capacity, max. | 30 | W |
- Switching voltage, max. AC | 110 | V |
- Switching voltage, max. DC | 125 | V |
- Switching current, max. | 1 | A |
- Lifespan, electrical at 30V, 1A | 10**5 | operations |
- Lifespan, mechanical | 5*10**7 | operations |
- Turn-on time, max. without chattering | 4 | ms |
- Turn-off time, max. without chattering | 4 | ms |
Watchdog, time-out time | 200 or 1600 | ms |
Operating temperature range | -40 .. +85 | °C |
Dimensions | 29x58x8 | mm |
Weight, min./max. | 12,7/12,85 | g |
Power consumption, all relais on/off 3,3V | 175/485 | mA |