X-AD14-20, X-AD12-20, X-AD12-16 |
![]() |
|
|
Low cost versions
The module is also available with slower AD converter and with 12 or 13 bit resolution.
| Module | Inputs | Resolution | Max. sample rate | Comment |
|---|---|---|---|---|
| X-AD14-20/F | 20 | 14 | 2,2 Msps | Temperature measurement |
| X-AD14-20/M | 20 | 14 | 0,8 Msps | Low power mode, temperature measurement |
| X-AD14-20/S | 20 | 14 | 0,4 Msps | Low power mode, temperature measurement |
| X-AD12-20/S | 20 | 12 | 1,2 Msps | Low power mode, temperature measurement |
| X-AD12-16/L | 16 | 12 | 0,8 Msps | Input range +-2,5V and +-10V |
| X-AD12-16/5 | 16 | 12 | 0,8 Msps | Input range +-2,5V and +-5V |
| Parameter | Value | Unit |
|---|---|---|
| Number of inputs: | ||
| - referenced to ground | 20 | - |
| - differential | 10 | - |
| Resolution, max. | 14 | Bit |
|
Input ranges: ± 10V, ± 5V, ± 2,5V, (± 2,0V), ± 1,25V, (± 1V), ± 500mV, ± 250mV Other ranges (on request): e.g.: 0 .. 20 mA, 4 .. 20 mA, ± 250 V, ± 100 V, ± 50 V |
6 | - |
| Conversion time per channel | 450 | ns |
| Overvoltage withstand capability (power on or off) | -37 ... +52 | V |
| Settle timer | 0,03 ... 30 | us |
| Special channels (on-board temperature, offset, ± 10V) | 8 | - |
| Temperature measurement: | ||
| - range | -40 .. +125 | °C |
| - precision at 25°C /-40°C ... +125°C | ±3/±4 | °C |
| - non-linearity | ±0,8 | °C |
| Operating temperature range | -40 .. +85 | °C |
| Dimensions | 29x58x8 | mm |
| Weight | 9,75 | g |
| Power consumption: | ||
| - typ. 3,3V | 147 | mA |
| - typ. +12V | 35 | mA |
| - typ. -12V | 40 | mA |
© SORCUS Computer GmbH ·
Im Breitspiel 5 ·
D-69126 Heidelberg ·
Tel.: +49(0)6221/3206-0 ·
www.sorcus.com
Questions and suggestions please mail to: